diff --git a/bin/wild-cluster-node-image-create b/bin/wild-cluster-node-image-create index d092bb8..1e156d3 100755 --- a/bin/wild-cluster-node-image-create +++ b/bin/wild-cluster-node-image-create @@ -51,77 +51,15 @@ else init_wild_env fi -# Configure basic settings if needed -if [ ! -f "${WC_HOME}/config.yaml" ] || [ -z "$(get_current_config "operator.email")" ]; then - print_header "Basic Configuration" - - # Detect current network for suggestions - CURRENT_IP=$(ip route get 8.8.8.8 | awk '{print $7; exit}' 2>/dev/null || echo "192.168.1.100") - GATEWAY_IP=$(ip route | grep default | awk '{print $3; exit}' 2>/dev/null || echo "192.168.1.1") - SUBNET_PREFIX=$(echo "${CURRENT_IP}" | cut -d. -f1-3) - print_info "Detected network: ${SUBNET_PREFIX}.x (gateway: ${GATEWAY_IP})" - - echo "This will configure basic settings for your wild-cloud deployment." - echo "" - - # Basic Information - current_email=$(get_current_config "operator.email") - email=$(prompt_with_default "Your email address (for Let's Encrypt certificates)" "" "${current_email}") - wild-config-set "operator.email" "${email}" - - # Domain Configuration - current_base_domain=$(get_current_config "cloud.baseDomain") - base_domain=$(prompt_with_default "Your base domain name (e.g., example.com)" "" "${current_base_domain}") - wild-config-set "cloud.baseDomain" "${base_domain}" - - current_domain=$(get_current_config "cloud.domain") - domain=$(prompt_with_default "Your public cloud domain" "cloud.${base_domain}" "${current_domain}") - wild-config-set "cloud.domain" "${domain}" - - current_internal_domain=$(get_current_config "cloud.internalDomain") - internal_domain=$(prompt_with_default "Your internal cloud domain" "internal.${domain}" "${current_internal_domain}") - wild-config-set "cloud.internalDomain" "${internal_domain}" - - # Derive cluster name from domain - cluster_name=$(echo "${domain}" | tr '.' '-' | tr '[:upper:]' '[:lower:]') - wild-config-set "cluster.name" "${cluster_name}" - print_info "Set cluster name to: ${cluster_name}" - - print_success "Basic configuration completed" - echo "" -fi - -# Configure cluster settings if needed +# Check for required configuration if [ -z "$(get_current_config "cluster.nodes.talos.version")" ] || [ -z "$(get_current_config "cluster.nodes.talos.schematicId")" ]; then - print_header "Kubernetes Cluster Configuration" - - current_talos_version=$(get_current_config "cluster.nodes.talos.version") - talos_version=$(prompt_with_default "Talos version" "v1.10.4" "${current_talos_version}") - wild-config-set "cluster.nodes.talos.version" "${talos_version}" - - # Talos schematic ID - current_schematic_id=$(get_current_config "cluster.nodes.talos.schematicId") - echo "" - print_info "Get your Talos schematic ID from: https://factory.talos.dev/" - print_info "This customizes Talos with the drivers needed for your hardware." - - # Look up default schematic ID from talos-schemas.yaml - default_schematic_id="" - schemas_file="${WC_ROOT}/setup/cluster-nodes/talos-schemas.yaml" - if [ -f "$schemas_file" ]; then - default_schematic_id=$(yq eval ".talos-schemas.\"${talos_version}\"" "$schemas_file" 2>/dev/null) - if [ -n "$default_schematic_id" ] && [ "$default_schematic_id" != "null" ]; then - print_info "Default schematic ID available for Talos $talos_version" - else - default_schematic_id="" - fi - fi - - schematic_id=$(prompt_with_default "Talos schematic ID" "${default_schematic_id}" "${current_schematic_id}") - wild-config-set "cluster.nodes.talos.schematicId" "${schematic_id}" - - print_success "Cluster configuration completed" - echo "" + print_header "Talos Configuration Required" + print_error "Missing required Talos configuration" + print_info "Please run 'wild-setup' first to configure your cluster" + print_info "Or set the required configuration manually:" + print_info " wild-config-set cluster.nodes.talos.version v1.10.4" + print_info " wild-config-set cluster.nodes.talos.schematicId YOUR_SCHEMATIC_ID" + exit 1 fi # ============================================================================= @@ -137,35 +75,11 @@ SCHEMATIC_ID=$(get_current_config cluster.nodes.talos.schematicId) print_info "Creating custom Talos installer image..." print_info "Talos version: $TALOS_VERSION" -# Check if schematic ID exists +# Validate schematic ID if [ -z "$SCHEMATIC_ID" ] || [ "$SCHEMATIC_ID" = "null" ]; then print_error "No schematic ID found in config.yaml" - print_info "You can get a schematic ID from: https://factory.talos.dev/" - - # Look up default schematic ID from talos-schemas.yaml - fallback_default="" - schemas_file="${WC_ROOT}/setup/cluster-nodes/talos-schemas.yaml" - if [ -f "$schemas_file" ]; then - fallback_default=$(yq eval ".talos-schemas.\"${TALOS_VERSION}\"" "$schemas_file" 2>/dev/null) - if [ -n "$fallback_default" ] && [ "$fallback_default" != "null" ]; then - print_info "Default schematic ID available for Talos $TALOS_VERSION" - read -p "Enter schematic ID [$fallback_default]: " -r SCHEMATIC_ID - if [ -z "$SCHEMATIC_ID" ]; then - SCHEMATIC_ID="$fallback_default" - fi - else - read -p "Enter schematic ID: " -r SCHEMATIC_ID - fi - else - read -p "Enter schematic ID: " -r SCHEMATIC_ID - fi - - if [ -n "$SCHEMATIC_ID" ]; then - wild-config-set "cluster.nodes.talos.schematicId" "$SCHEMATIC_ID" - else - print_error "Schematic ID required for installer image generation" - exit 1 - fi + print_info "Please run 'wild-setup' first to configure your cluster" + exit 1 fi print_info "Schematic ID: $SCHEMATIC_ID" @@ -190,12 +104,15 @@ print_info "Installer URL: $INSTALLER_URL" print_header "Downloading and Caching PXE Boot Assets" -# Create cache directories +# Create cache directories organized by schematic ID CACHE_DIR="${WC_HOME}/.wildcloud" -PXE_CACHE_DIR="${CACHE_DIR}/pxe" -IPXE_CACHE_DIR="${CACHE_DIR}/ipxe" +SCHEMATIC_CACHE_DIR="${CACHE_DIR}/node-boot-assets/${SCHEMATIC_ID}" +PXE_CACHE_DIR="${SCHEMATIC_CACHE_DIR}/pxe" +IPXE_CACHE_DIR="${SCHEMATIC_CACHE_DIR}/ipxe" +ISO_CACHE_DIR="${SCHEMATIC_CACHE_DIR}/iso" mkdir -p "$PXE_CACHE_DIR/amd64" mkdir -p "$IPXE_CACHE_DIR" +mkdir -p "$ISO_CACHE_DIR" # Download Talos kernel and initramfs for PXE boot print_info "Downloading Talos PXE assets..." @@ -248,19 +165,30 @@ download_asset "http://boot.ipxe.org/ipxe.efi" "${IPXE_CACHE_DIR}/ipxe.efi" "iPX download_asset "http://boot.ipxe.org/undionly.kpxe" "${IPXE_CACHE_DIR}/undionly.kpxe" "iPXE BIOS bootloader" download_asset "http://boot.ipxe.org/arm64-efi/ipxe.efi" "${IPXE_CACHE_DIR}/ipxe-arm64.efi" "iPXE ARM64 EFI bootloader" +# Download Talos ISO +print_info "Downloading Talos ISO..." +ISO_URL="https://factory.talos.dev/image/${SCHEMATIC_ID}/${TALOS_VERSION}/metal-amd64.iso" +ISO_FILENAME="talos-${TALOS_VERSION}-metal-amd64.iso" +ISO_PATH="${ISO_CACHE_DIR}/${ISO_FILENAME}" +download_asset "$ISO_URL" "$ISO_PATH" "Talos ISO" + echo "" print_success "All assets downloaded and cached!" echo "" -print_info "Cached assets:" +print_info "Cached assets for schematic $SCHEMATIC_ID:" echo " Talos kernel: $KERNEL_PATH" echo " Talos initramfs: $INITRAMFS_PATH" +echo " Talos ISO: $ISO_PATH" echo " iPXE EFI: ${IPXE_CACHE_DIR}/ipxe.efi" echo " iPXE BIOS: ${IPXE_CACHE_DIR}/undionly.kpxe" echo " iPXE ARM64: ${IPXE_CACHE_DIR}/ipxe-arm64.efi" echo "" -print_info "Use this URL for:" -echo " - PXE boot configuration (update boot.ipxe kernel line)" -echo " - ISO creation: curl -LO https://$INSTALLER_URL" -echo " - USB creation: dd if=talos-installer.iso of=/dev/sdX" +print_info "Cache location: $SCHEMATIC_CACHE_DIR" +echo "" +print_info "Use these assets for:" +echo " - PXE boot: Use kernel and initramfs from cache" +echo " - USB creation: Use ISO file for dd or imaging tools" +echo " Example: sudo dd if=$ISO_PATH of=/dev/sdX bs=4M status=progress" +echo " - Custom installer: https://$INSTALLER_URL" echo "" print_success "Installer image generation and asset caching completed!" \ No newline at end of file diff --git a/bin/wild-dnsmasq-install b/bin/wild-dnsmasq-install index 13db936..fece54c 100755 --- a/bin/wild-dnsmasq-install +++ b/bin/wild-dnsmasq-install @@ -2,16 +2,22 @@ # Parse command line arguments INSTALL_MODE=false +SCHEMATIC_ID_OVERRIDE="" while [[ $# -gt 0 ]]; do case $1 in --install) INSTALL_MODE=true shift ;; + --schematic-id) + SCHEMATIC_ID_OVERRIDE="$2" + shift 2 + ;; *) echo "Unknown option: $1" - echo "Usage: $0 [--install]" - echo " --install Copy bundle to DNSMasq server and run installation" + echo "Usage: $0 [--install] [--schematic-id SCHEMATIC_ID]" + echo " --install Copy bundle to DNSMasq server and run installation" + echo " --schematic-id ID Use specific schematic ID instead of config default" exit 1 ;; esac @@ -68,17 +74,33 @@ PXE_WEB_ROOT="${BUNDLE_DIR}/ipxe-web" mkdir -p "${PXE_WEB_ROOT}/amd64" cp "${DNSMASQ_SETUP_DIR}/boot.ipxe" "${PXE_WEB_ROOT}/boot.ipxe" -# Define cache directories +# Get schematic ID from override or config +if [ -n "$SCHEMATIC_ID_OVERRIDE" ]; then + SCHEMATIC_ID="$SCHEMATIC_ID_OVERRIDE" + echo "Using schematic ID from command line: $SCHEMATIC_ID" +else + SCHEMATIC_ID=$(wild-config cluster.nodes.talos.schematicId) + if [ -z "$SCHEMATIC_ID" ] || [ "$SCHEMATIC_ID" = "null" ]; then + echo "Error: No schematic ID found in config" + echo "Please run 'wild-setup' first to configure your cluster" + echo "Or specify one with --schematic-id option" + exit 1 + fi + echo "Using schematic ID from config: $SCHEMATIC_ID" +fi + +# Define cache directories using new structure CACHE_DIR="${WC_HOME}/.wildcloud" -PXE_CACHE_DIR="${CACHE_DIR}/pxe" -IPXE_CACHE_DIR="${CACHE_DIR}/ipxe" +SCHEMATIC_CACHE_DIR="${CACHE_DIR}/node-boot-assets/${SCHEMATIC_ID}" +PXE_CACHE_DIR="${SCHEMATIC_CACHE_DIR}/pxe" +IPXE_CACHE_DIR="${SCHEMATIC_CACHE_DIR}/ipxe" # Check if cached assets exist KERNEL_CACHE_PATH="${PXE_CACHE_DIR}/amd64/vmlinuz" INITRAMFS_CACHE_PATH="${PXE_CACHE_DIR}/amd64/initramfs.xz" if [ ! -f "${KERNEL_CACHE_PATH}" ] || [ ! -f "${INITRAMFS_CACHE_PATH}" ]; then - echo "Error: Talos PXE assets not found in cache" + echo "Error: Talos PXE assets not found in cache for schematic ID: ${SCHEMATIC_ID}" echo "Expected locations:" echo " Kernel: ${KERNEL_CACHE_PATH}" echo " Initramfs: ${INITRAMFS_CACHE_PATH}" @@ -107,7 +129,7 @@ IPXE_BIOS_CACHE="${IPXE_CACHE_DIR}/undionly.kpxe" IPXE_ARM64_CACHE="${IPXE_CACHE_DIR}/ipxe-arm64.efi" if [ ! -f "${IPXE_EFI_CACHE}" ] || [ ! -f "${IPXE_BIOS_CACHE}" ] || [ ! -f "${IPXE_ARM64_CACHE}" ]; then - echo "Error: iPXE bootloader assets not found in cache" + echo "Error: iPXE bootloader assets not found in cache for schematic ID: ${SCHEMATIC_ID}" echo "Expected locations:" echo " iPXE EFI: ${IPXE_EFI_CACHE}" echo " iPXE BIOS: ${IPXE_BIOS_CACHE}" diff --git a/bin/wild-setup-cluster b/bin/wild-setup-cluster index 504bbd4..cb96702 100755 --- a/bin/wild-setup-cluster +++ b/bin/wild-setup-cluster @@ -89,6 +89,76 @@ else print_info "Skipping: Installer Image Generation" fi +# ============================================================================= +# Network and Cluster Configuration +# ============================================================================= + +# Configure network settings +if [ -z "$(get_current_config "cloud.router.ip")" ]; then + print_header "Network Configuration" + + CURRENT_IP=$(ip route get 8.8.8.8 | awk '{print $7; exit}' 2>/dev/null || echo "192.168.1.100") + GATEWAY_IP=$(ip route | grep default | awk '{print $3; exit}' 2>/dev/null || echo "192.168.1.1") + SUBNET_PREFIX=$(echo "${CURRENT_IP}" | cut -d. -f1-3) + + prompt_if_unset_config "cloud.router.ip" "Router/Gateway IP" "${GATEWAY_IP}" + prompt_if_unset_config "cloud.dns.ip" "DNS server IP (dnsmasq machine)" "${SUBNET_PREFIX}.50" + prompt_if_unset_config "cloud.dhcpRange" "DHCP range for dnsmasq" "${SUBNET_PREFIX}.100,${SUBNET_PREFIX}.200" + prompt_if_unset_config "cloud.dnsmasq.interface" "Network interface for dnsmasq" "eth0" + prompt_if_unset_config "cloud.dns.externalResolver" "External DNS resolver" "1.1.1.1" + + print_success "Network configuration completed" + echo "" +fi + +# Configure cluster settings +print_header "Kubernetes Cluster Configuration" + +CURRENT_IP=$(ip route get 8.8.8.8 | awk '{print $7; exit}' 2>/dev/null || echo "192.168.1.100") +SUBNET_PREFIX=$(echo "${CURRENT_IP}" | cut -d. -f1-3) + +# Talos version +prompt_if_unset_config "cluster.nodes.talos.version" "Talos version" "v1.10.4" +talos_version=$(wild-config "cluster.nodes.talos.version") + +# MetalLB IP address pool +prompt_if_unset_config "cluster.ipAddressPool" "MetalLB IP address pool" "${SUBNET_PREFIX}.80-${SUBNET_PREFIX}.89" +ip_pool=$(wild-config "cluster.ipAddressPool") + +# Load balancer IP (automatically set to first address in the pool if not set) +current_lb_ip=$(get_current_config "cluster.loadBalancerIp") +if [ -z "$current_lb_ip" ] || [ "$current_lb_ip" = "null" ]; then + lb_ip=$(echo "${ip_pool}" | cut -d'-' -f1) + wild-config-set "cluster.loadBalancerIp" "${lb_ip}" + print_info "Set load balancer IP to: ${lb_ip} (first IP in MetalLB pool)" +fi + +# Talos schematic ID +current_schematic_id=$(get_current_config "cluster.nodes.talos.schematicId") +if [ -z "$current_schematic_id" ] || [ "$current_schematic_id" = "null" ]; then + echo "" + print_info "Get your Talos schematic ID from: https://factory.talos.dev/" + print_info "This customizes Talos with the drivers needed for your hardware." + + # Use current schematic ID from config as default + default_schematic_id=$(get_current_config "cluster.nodes.talos.schematicId") + if [ -n "$default_schematic_id" ] && [ "$default_schematic_id" != "null" ]; then + print_info "Using schematic ID from config for Talos $talos_version" + else + default_schematic_id="" + fi + + schematic_id=$(prompt_with_default "Talos schematic ID" "${default_schematic_id}" "${current_schematic_id}") + wild-config-set "cluster.nodes.talos.schematicId" "${schematic_id}" +fi + +# External DNS +cluster_name=$(get_current_config "cluster.name") +prompt_if_unset_config "cluster.externalDns.ownerId" "External DNS owner ID" "external-dns-${cluster_name}" + +print_success "Cluster configuration completed" +echo "" + # ============================================================================= # Node Hardware Detection # ============================================================================= @@ -96,76 +166,6 @@ fi if [ "${SKIP_HARDWARE}" = false ]; then print_header "Node Hardware Detection" - # Configure network settings - if [ -z "$(get_current_config "cloud.router.ip")" ]; then - print_header "Network Configuration" - - CURRENT_IP=$(ip route get 8.8.8.8 | awk '{print $7; exit}' 2>/dev/null || echo "192.168.1.100") - GATEWAY_IP=$(ip route | grep default | awk '{print $3; exit}' 2>/dev/null || echo "192.168.1.1") - SUBNET_PREFIX=$(echo "${CURRENT_IP}" | cut -d. -f1-3) - - prompt_if_unset_config "cloud.router.ip" "Router/Gateway IP" "${GATEWAY_IP}" - prompt_if_unset_config "cloud.dns.ip" "DNS server IP (dnsmasq machine)" "${SUBNET_PREFIX}.50" - prompt_if_unset_config "cloud.dhcpRange" "DHCP range for dnsmasq" "${SUBNET_PREFIX}.100,${SUBNET_PREFIX}.200" - prompt_if_unset_config "cloud.dnsmasq.interface" "Network interface for dnsmasq" "eth0" - prompt_if_unset_config "cloud.dns.externalResolver" "External DNS resolver" "1.1.1.1" - - print_success "Network configuration completed" - echo "" - fi - - # Configure cluster settings - print_header "Kubernetes Cluster Configuration" - - CURRENT_IP=$(ip route get 8.8.8.8 | awk '{print $7; exit}' 2>/dev/null || echo "192.168.1.100") - SUBNET_PREFIX=$(echo "${CURRENT_IP}" | cut -d. -f1-3) - - # Talos version - prompt_if_unset_config "cluster.nodes.talos.version" "Talos version" "v1.10.4" - talos_version=$(wild-config "cluster.nodes.talos.version") - - # MetalLB IP address pool - prompt_if_unset_config "cluster.ipAddressPool" "MetalLB IP address pool" "${SUBNET_PREFIX}.80-${SUBNET_PREFIX}.89" - ip_pool=$(wild-config "cluster.ipAddressPool") - - # Load balancer IP (automatically set to first address in the pool if not set) - current_lb_ip=$(get_current_config "cluster.loadBalancerIp") - if [ -z "$current_lb_ip" ] || [ "$current_lb_ip" = "null" ]; then - lb_ip=$(echo "${ip_pool}" | cut -d'-' -f1) - wild-config-set "cluster.loadBalancerIp" "${lb_ip}" - print_info "Set load balancer IP to: ${lb_ip} (first IP in MetalLB pool)" - fi - - # Talos schematic ID - current_schematic_id=$(get_current_config "cluster.nodes.talos.schematicId") - if [ -z "$current_schematic_id" ] || [ "$current_schematic_id" = "null" ]; then - echo "" - print_info "Get your Talos schematic ID from: https://factory.talos.dev/" - print_info "This customizes Talos with the drivers needed for your hardware." - - # Look up default schematic ID from talos-schemas.yaml - default_schematic_id="" - schemas_file="${WC_ROOT}/setup/cluster-nodes/talos-schemas.yaml" - if [ -f "$schemas_file" ]; then - default_schematic_id=$(yq eval ".talos-schemas.\"${talos_version}\"" "$schemas_file" 2>/dev/null) - if [ -n "$default_schematic_id" ] && [ "$default_schematic_id" != "null" ]; then - print_info "Default schematic ID available for Talos $talos_version" - else - default_schematic_id="" - fi - fi - - schematic_id=$(prompt_with_default "Talos schematic ID" "${default_schematic_id}" "${current_schematic_id}") - wild-config-set "cluster.nodes.talos.schematicId" "${schematic_id}" - fi - - # External DNS - cluster_name=$(get_current_config "cluster.name") - prompt_if_unset_config "cluster.externalDns.ownerId" "External DNS owner ID" "external-dns-${cluster_name}" - - print_success "Cluster configuration completed" - echo "" - print_info "This phase will help you register Talos nodes by discovering their hardware." print_info "You'll need nodes booted in maintenance mode and accessible via IP." echo "" @@ -321,6 +321,16 @@ if [ "${SKIP_HARDWARE}" = false ]; then wild-config-set "cluster.nodes.active.\"${TARGET_IP}\".disk" "$SELECTED_DISK" wild-config-set "cluster.nodes.active.\"${TARGET_IP}\".control" "true" + # Copy current Talos version and schematic ID to this node + current_talos_version=$(get_current_config "cluster.nodes.talos.version") + current_schematic_id=$(get_current_config "cluster.nodes.talos.schematicId") + if [ -n "$current_talos_version" ] && [ "$current_talos_version" != "null" ]; then + wild-config-set "cluster.nodes.active.\"${TARGET_IP}\".version" "$current_talos_version" + fi + if [ -n "$current_schematic_id" ] && [ "$current_schematic_id" != "null" ]; then + wild-config-set "cluster.nodes.active.\"${TARGET_IP}\".schematicId" "$current_schematic_id" + fi + print_success "Node $TARGET_IP registered successfully" # Generate machine config. @@ -417,6 +427,16 @@ if [ "${SKIP_HARDWARE}" = false ]; then wild-config-set "cluster.nodes.active.\"${WORKER_IP}\".disk" "$SELECTED_DISK" wild-config-set "cluster.nodes.active.\"${WORKER_IP}\".control" "false" + # Copy current Talos version and schematic ID to this node + current_talos_version=$(get_current_config "cluster.nodes.talos.version") + current_schematic_id=$(get_current_config "cluster.nodes.talos.schematicId") + if [ -n "$current_talos_version" ] && [ "$current_talos_version" != "null" ]; then + wild-config-set "cluster.nodes.active.\"${WORKER_IP}\".version" "$current_talos_version" + fi + if [ -n "$current_schematic_id" ] && [ "$current_schematic_id" != "null" ]; then + wild-config-set "cluster.nodes.active.\"${WORKER_IP}\".schematicId" "$current_schematic_id" + fi + print_success "Worker node $WORKER_IP registered successfully:" print_info " - IP: $WORKER_IP" print_info " - Interface: $INTERFACE" diff --git a/bin/wild-setup-scaffold b/bin/wild-setup-scaffold index a15d44d..653a498 100755 --- a/bin/wild-setup-scaffold +++ b/bin/wild-setup-scaffold @@ -145,43 +145,26 @@ fi # BASIC CONFIGURATION # ============================================================================= -# Configure basic settings -if [ ! -f "${WC_HOME}/config.yaml" ] || [ -z "$(get_current_config "operator.email")" ]; then - print_header "Basic Configuration" - - # Detect current network for suggestions - CURRENT_IP=$(ip route get 8.8.8.8 | awk '{print $7; exit}' 2>/dev/null || echo "192.168.1.100") - GATEWAY_IP=$(ip route | grep default | awk '{print $3; exit}' 2>/dev/null || echo "192.168.1.1") - SUBNET_PREFIX=$(echo "${CURRENT_IP}" | cut -d. -f1-3) - print_info "Detected network: ${SUBNET_PREFIX}.x (gateway: ${GATEWAY_IP})" - - echo "This will configure basic settings for your wild-cloud deployment." - echo "" - - # Basic Information - prompt_if_unset_config "operator.email" "Your email address (for Let's Encrypt certificates)" "" +# Basic Information +prompt_if_unset_config "operator.email" "Your email address (for Let's Encrypt certificates)" "" - # Domain Configuration - prompt_if_unset_config "cloud.baseDomain" "Your base domain name (e.g., example.com)" "" - - # Get base domain to use as default for cloud domain - base_domain=$(wild-config "cloud.baseDomain") - prompt_if_unset_config "cloud.domain" "Your public cloud domain" "cloud.${base_domain}" - - # Get cloud domain to use as default for internal domain - domain=$(wild-config "cloud.domain") - prompt_if_unset_config "cloud.internalDomain" "Your internal cloud domain" "internal.${domain}" +# Domain Configuration +prompt_if_unset_config "cloud.baseDomain" "Your base domain name (e.g., example.com)" "" - # Derive cluster name from domain if not already set - current_cluster_name=$(get_current_config "cluster.name") - if [ -z "$current_cluster_name" ] || [ "$current_cluster_name" = "null" ]; then - cluster_name=$(echo "${domain}" | tr '.' '-' | tr '[:upper:]' '[:lower:]') - wild-config-set "cluster.name" "${cluster_name}" - print_info "Set cluster name to: ${cluster_name}" - fi - - print_success "Basic configuration completed" - echo "" +# Get base domain to use as default for cloud domain +base_domain=$(wild-config "cloud.baseDomain") +prompt_if_unset_config "cloud.domain" "Your public cloud domain" "cloud.${base_domain}" + +# Get cloud domain to use as default for internal domain +domain=$(wild-config "cloud.domain") +prompt_if_unset_config "cloud.internalDomain" "Your internal cloud domain" "internal.${domain}" + +# Derive cluster name from domain if not already set +current_cluster_name=$(get_current_config "cluster.name") +if [ -z "$current_cluster_name" ] || [ "$current_cluster_name" = "null" ]; then + cluster_name=$(echo "${domain}" | tr '.' '-' | tr '[:upper:]' '[:lower:]') + wild-config-set "cluster.name" "${cluster_name}" + print_info "Set cluster name to: ${cluster_name}" fi # ============================================================================= diff --git a/bin/wild-talos-iso b/bin/wild-talos-iso deleted file mode 100755 index 3715847..0000000 --- a/bin/wild-talos-iso +++ /dev/null @@ -1,140 +0,0 @@ -#!/bin/bash - -# Talos ISO download script -# Downloads custom Talos ISO with system extensions for USB boot - -set -euo pipefail - -# Initialize Wild-Cloud environment -if [ -z "${WC_ROOT}" ]; then - print "WC_ROOT is not set." - exit 1 -else - source "${WC_ROOT}/scripts/common.sh" - init_wild_env -fi - -CONFIG_FILE="${WC_HOME}/config.yaml" -ISO_DIR="${WC_HOME}/.wildcloud/iso" -FORCE_DOWNLOAD=false - -# Parse arguments -while [[ $# -gt 0 ]]; do - case $1 in - --force) - FORCE_DOWNLOAD=true - shift - ;; - -h|--help) - echo "Usage: wild-talos-iso [--force]" - echo "" - echo "Downloads custom Talos ISO with system extensions for USB boot." - echo "" - echo "Options:" - echo " --force Force re-download even if ISO already exists" - echo " -h, --help Show this help message" - echo "" - echo "This script:" - echo " 1. Gets schematic ID and Talos version from config.yaml" - echo " 2. Downloads custom ISO from Talos Image Factory" - echo " 3. Saves ISO to .wildcloud/iso/ directory" - echo "" - echo "The ISO includes extensions configured in config.yaml:" - echo " (.cluster.nodes.talos.schematic.customization.systemExtensions)" - exit 0 - ;; - *) - echo "Unknown option: $1" - echo "Use --help for usage information" - exit 1 - ;; - esac -done - -echo "Downloading custom Talos ISO with system extensions..." - -# Get Talos version and schematic ID from config -TALOS_VERSION=$(yq eval '.cluster.nodes.talos.version' "$CONFIG_FILE") -SCHEMATIC_ID=$(yq eval '.cluster.nodes.talos.schematicId // ""' "$CONFIG_FILE") - -if [ -z "$TALOS_VERSION" ] || [ "$TALOS_VERSION" = "null" ]; then - echo "Error: No Talos version found in config.yaml at .cluster.nodes.talos.version" - exit 1 -fi - -if [ -z "$SCHEMATIC_ID" ] || [ "$SCHEMATIC_ID" = "null" ]; then - echo "Error: No schematic ID found in config.yaml" - echo "Run 'wild-talos-schema' first to upload schematic and get ID" - exit 1 -fi - -echo "Talos version: $TALOS_VERSION" -echo "Schematic ID: $SCHEMATIC_ID" -echo "" -echo "ISO includes extensions:" -yq eval '.cluster.nodes.talos.schematic.customization.systemExtensions.officialExtensions[]' "$CONFIG_FILE" | sed 's/^/ - /' -echo "" - -# Create ISO directory -mkdir -p "$ISO_DIR" - -# Define ISO filename and path -ISO_FILENAME="talos-${TALOS_VERSION}-metal-amd64.iso" -ISO_PATH="${ISO_DIR}/${ISO_FILENAME}" - -# Check if ISO already exists -if [ -f "$ISO_PATH" ] && [ "$FORCE_DOWNLOAD" = false ]; then - echo "✅ ISO already exists: $ISO_PATH" - echo "Use --force to re-download" - echo "" - echo "To create a bootable USB:" - echo " See docs/node_setup.md for USB creation instructions" - exit 0 -fi - -# Download ISO from Image Factory -ISO_URL="https://factory.talos.dev/image/${SCHEMATIC_ID}/${TALOS_VERSION}/metal-amd64.iso" -echo "Downloading ISO from: $ISO_URL" -echo "Saving to: $ISO_PATH" -echo "" - -# Download with progress bar -if command -v wget >/dev/null 2>&1; then - wget --progress=bar:force -O "$ISO_PATH" "$ISO_URL" -elif command -v curl >/dev/null 2>&1; then - curl -L --progress-bar -o "$ISO_PATH" "$ISO_URL" -else - echo "Error: Neither wget nor curl is available for downloading" - exit 1 -fi - -# Verify download -if [ ! -f "$ISO_PATH" ] || [ ! -s "$ISO_PATH" ]; then - echo "Error: Download failed or file is empty" - rm -f "$ISO_PATH" - exit 1 -fi - -# Get file size for verification -FILE_SIZE=$(du -h "$ISO_PATH" | cut -f1) - -echo "" -echo "✅ Custom Talos ISO downloaded successfully!" -echo "" -echo "ISO Details:" -echo " File: $ISO_PATH" -echo " Size: $FILE_SIZE" -echo " Version: $TALOS_VERSION" -echo " Extensions: $(yq eval '.cluster.nodes.talos.schematic.customization.systemExtensions.officialExtensions | length' "$CONFIG_FILE") extensions included" -echo " Auto-wipe: Enabled (will wipe existing Talos installations)" -echo "" -echo "Next steps:" -echo "1. Create bootable USB drive (see docs/node_setup.md)" -echo "2. Boot target machine from USB" -echo "3. Run hardware detection: ./detect-node-hardware.sh " -echo "4. Apply machine configuration" -echo "" -echo "USB Creation Quick Reference:" -echo " Linux: sudo dd if=$ISO_PATH of=/dev/sdX bs=4M status=progress" -echo " macOS: sudo dd if=$ISO_PATH of=/dev/rdiskX bs=4m" -echo " Windows: Use Rufus, Balena Etcher, or similar tool" \ No newline at end of file diff --git a/setup/cluster-nodes/talos-schemas.yaml b/setup/cluster-nodes/talos-schemas.yaml index 37be736..3c8f812 100644 --- a/setup/cluster-nodes/talos-schemas.yaml +++ b/setup/cluster-nodes/talos-schemas.yaml @@ -12,18 +12,36 @@ # 3. Generate the schematic # 4. Add the version and schematic ID below -# Format: "version": "schematic-id" -schematic: - customization: - extraKernelArgs: - - -talos.halt_if_installed - systemExtensions: - officialExtensions: - - siderolabs/gvisor - - siderolabs/intel-ucode - - siderolabs/iscsi-tools - - siderolabs/util-linux-tools - -talos-schemas: - "v1.10.3": "e6230b0db3fd355a0bb77a9de74af41a9f3edd168f913cbd94807629a2116d07" - "v1.10.4": "434a0300db532066f1098e05ac068159371d00f0aba0a3103a0e826e83825c82" +# Format: Each schematic ID is the primary key with version and definition nested + "434a0300db532066f1098e05ac068159371d00f0aba0a3103a0e826e83825c82": + version: "v1.10.5" + architecture: "amd64" + secureBoot: false + schematic: + customization: + extraKernelArgs: + - -talos.halt_if_installed + systemExtensions: + officialExtensions: + - siderolabs/gvisor + - siderolabs/intel-ucode + - siderolabs/iscsi-tools + - siderolabs/util-linux-tools + "f309e674d9ad94655e2cf8a43ea1432475c717cd1885f596bd7ec852b900bc5b": + version: "v1.10.4" + architecture: "amd64" + secureBoot: true + schematic: + customization: + systemExtensions: + officialExtensions: + - siderolabs/gvisor + - siderolabs/intel-ucode + - siderolabs/iscsi-tools + - siderolabs/nvidia-container-toolkit-lts + - siderolabs/nvidia-container-toolkit-production + - siderolabs/nvidia-fabricmanager-lts + - siderolabs/nvidia-fabricmanager-production + - siderolabs/nvidia-open-gpu-kernel-modules-lts + - siderolabs/nvidia-open-gpu-kernel-modules-production + - siderolabs/util-linux-tools"